Nikon total station npl 352 manual
To measure less reflective objects, use the N-prism reflectorless mode. Measurement in Reflectorless mode The color and condition of the target surface also affect the measurable distance, even if the targeted objects are the same. Some less-reflective targets may not be measured. In this case, try to throw a shadow on the target.
Targets with completely flat surfaces, such as mirrors, cannot be measured unless the beam and the target are perpendicular to each other. Sighting a prism in Reflectorless mode may cause an excessive signal error.
In the Reflectorless mode, the beam passing area is shown by a circle in crosshairs on the Beam passing area telescope reticle. If the target is smaller than the circle and there is something highly reflective in the background, the measured data may be affected by these adverse conditions. When an obstacle momentarily passes through the beam between the instrument and the target for example, passing cars on the road , the false data short distance is deleted automatically.
However, if the amount of reflection is almost the same and the difference in distances between the correct and the false data is less than two meters, it may cause an error in measurements. Make sure there are no obstacles between the instrument and the target when taking measurents. When you need to take measurements across a road or a place where vehicles or other objects are frequently moving, take several measurements to a target for the best result. Assemble the reflector sheet as shown in Figure 2.
Assemble the prism reflector as shown in Figure 2. Adjust the height of the tribrach adaptor see page If necessary, change the direction of the prism see page Set the prism constant see page Set the position of the target plate see page Detailed instructions for Step 2 through Step 5 are provided on the following pages.
To use the prism reflector with a NPL series instrument, use the lower height setting. To adjust the height of the tribrach adapter: 1. Remove the height adjustment screw from the tribrach adapter. Slide the tribrach adapter up or down the prism holder mount until the height adjustment screw holes on the prism holder mount and on the tribrach adapter are aligned.
Replace and tighten the adjustment screw. Prism holder mount Height adjustment screw Changing the direction of the prism To change the direction of the prism: 1. Release the rotation clamp. To do this, turn the clamp lever counterclockwise. Turn the upper plate of the tribrach adapter Clamp until the prism is facing in the required direction. Clamp lever 3. Fasten the rotation clamp. To do this, turn the clamp lever clockwise. Unclamp Setting the prism constant Attach the prism to the single prism holder.
Set the prism constant. For more information, see Measurement settings, page If your prism constant is not 0mm, then directly enter the prism constant value in the Const field. For example, if your prism constant is 30mm, enter 30mm in the Const field on the instrument. B Tip — When using a prism at a short distance, set the prism at a slight angle to the sighting axis, rather than completely square.
Setting the position of the target plate To set the position of the target plate: 1. Use the two set screws supplied to attach Center on axis the target plate to the single prism holder. Move the target plate within the screw holes until the apex of the wedge pattern is aligned with the vertical axis of the prism and the tribrach adapter. By averaging the Face-1 and Face-2 measurement values, you can cancel out most constant mechanical errors.
Some errors, such as vertical axis error, cannot be cancelled out by averaging Face-1 and Face-2 measurements. A Face-2 measurement is made with the vertical circle positioned to the right of the telescope eyepiece. See Figure 2. Face-1 Face-2 Figure 2. To turn on the instrument, press [PWR]. The start-up screen appears. It shows the current temperature, pressure, date, and time.
Then press [ENT]. If you want to initialize the horizontal angle, rotate the alidade. Tilt the telescope until it passes the horizontal position on Face For more information, see page Once you start to use an initialized HA, you must rotate the alidade to initialize the HA every time you turn on the instrument. If you do this, you can maintain a fixed HA orientation even if the instrument has moved while it is turned off. If you tilt the telescope before you rotate the alidade, the horizontal angle is not initialized, and the instrument uses the previous HA reading.
Then do one of the following: Press The Language Pack is a set of up to three different languages installed on the instrument from which the user can select. Several Language Packs are available for the Nikon total stations.
To select a different language, power on the instrument and press [ESC] and [3] at the Tilt Telescope screen. The Select Language screen appears. Up to three languages are available in the installed Language Pack. The screen shows which languages are currently available on the instrument. The current language selection is highlighted. The instrument reboots and displays the start-up Tilt Telescope screen in the selected language. Language Pack 1 is the default Language Pack installed at the factory.
Other Language Packs can be installed at an authorized Nikon total station service provider. The Regional Configuration screen appears only after the language configuration is complete, the instrument has rebooted, and the telescope has been tilted. To change the regional configuration pre-sets: 1. Follow the steps in Selecting a Language, page After the instrument reboots and the telescope is tilted, the Regional Configuration screen appears.
If you do not want to change the current settings, press [ESC] and quit. The instrument will continue to use the last settings that were configured. The settings affected by the Regional Configuration screen are: Table 3. For more information, see Settings, page Display and Key Functions 3. Table 3. Turns the backlight on or off.
Provides access to the 2-switch window if held down for one second. Records measured data, moves on to the next screen, or confirms and accepts the entered data in input mode.
In numeric or alphanumeric mode, deletes input. Starts distance measurement, using the measure mode settings for the [MSR1] key. Displays measurement mode settings, if held down for one second. Moves to the next available display screen. In numeric mode, enters 7. In alphanumeric mode, enters A, B, C, or 7. Displays the Stakeout menu.
Shows stakeout settings, if held down for one second. In numeric mode, enters 8. In alphanumeric mode, enters D, E, F, or 8. Displays the Offset Point Measurement menu. In numeric mode, enters 9. In alphanumeric mode, enters G, H, I, or 9. Displays the Programs menu, which contains additional measuring programs.
In numeric mode, enters 4. In alphanumeric mode, enters J, K, L, or 4. In alphanumeric mode, enters M, N, O, or 5. In numeric mode, enters 6. In alphanumeric mode, enters P, Q, R, or 6. In numeric mode, enters 1.
In alphanumeric mode, enters S, T, U, or 1. Executes the function that is assigned to the [USR2] key. In numeric mode, enters 2. In alphanumeric mode, enters V, W, X, or 2.
Opens a window where you can enter a code. The default code value is the last code entered. In numeric mode, enters 3. In alphanumeric mode, enters Y, Z, a space, or 3.
In numeric mode, enters — minus. In alphanumeric mode, enters. Displays the Bubble indicator. In numeric mode, enters 0. It contains icons that indicate Status bar the status of various system functions. If this icon is blinking rapidly, the signal is low. If this icon is blinking slowly, there is no signal. If there is no icon, analog power for EDM is off. Input mode indicator The Input mode indicator only appears when you are entering points or coordinates. It shows the data input mode: Battery indicator Input mode is numeric.
Press a key on the number pad to enter the number printed on the key. Input mode is alphabetic. Press a key on the number pad to enter the first letter printed beside the key. Press the key repeatedly to cycle through all the letters assigned to that key. For example, to enter the letter O in alphabetic mode, press [5] three times. To adjust the 2-switch window Use the 2-switch window to adjust lighting and sound settings for the instrument. To open the 2-switch window from any screen, hold down the Illumination key for one second.
To cycle through the settings for a switch, press the number beside that switch. For example, to turn the backlight on or off, press [1]. Then press [ENT] to cycle through the settings for that switch. Switch 1 backlight LCD backlight is on. LCD backlight is off. Switch 2 Sound Sound is on.
Sound is off. Contrast adjustment window When the 2-switch window is open, press [] to display the contrast adjustment window. The arrow indicates the current contrast level. To return to the 2-switch window, press []. When you have finished changing display light and sound settings, press [ESC] to close the 2-switch or contrast adjustment window. To move to the next available screen, press [DSP]. When the secondary distance unit is set, an additional screen is available. For information on setting the secondary distance unit, see page Smaller units are impractical in the field.
This does not affect calculations. The precise value is used internally in all cases. Hold down [DSP] for one second. Use the and softkeys to scroll through the list of items that can be displayed for this item.
To save your changes, press the Save softkey. The DSP screens show the items you have selected. Except for the none item, you cannot display the same item on more than one line of the same screen. You can also customize the displayed items in Stakeout. Header characters The following header characters can be used in DSP screens: A colon : indicates that tilt correction is applied to the value. A hash symbol indicates that tilt correction is off. The input mode indicator in the status bar changes to show the current input mode.
When the cursor is in a height HT field, only numeric input mode is available. Quick code measurement mode 1. The PT field shows the default point name.
Press any numeric key [0] through [9] to start measuring and recording points. A list of the numeric keys and their assigned feature codes appears on the right side of the screen. For example, when you press [6], the code assigned to 6 is selected, and the instrument starts a measurement. If you have set the record mode to Confirm see Measurement settings, page 60 , the Record PT screen appears after each measurement.
Do one of the following: — To record the point, press [ENT]. Then press the Edit softkey. You can use the List and Stack softkeys to enter the code. Qcode observations To enter the Quick code observation routine, press the Qcode softkey. In this function, you can use the ten numeric keys to both select a feature code and shoot a point. To change the measurement mode for the Quick code observation, press the Sett softkey.
Enter the height of the target, or press the Stack softkey to display the HT stack. The HT stack stores the last 20 HT values entered. Enter the ambient temperature and pressure. The ppm value is updated automatically. Selecting the target set A target set specifies settings for the target type, the prism constant, and height of target. When you change the selected target set, all three settings are changed. You can use this function to quickly switch between two types of target, such as a reflector sheet and a prism.
You can prepare up to five target sets. Then either press [3], or select Target and press [ENT]. If you leave it blank, the current HT value is always applied to the measurement. If you have specified a value for HT, this value is also copied to the current HT.
Then either press [4], or select Note and press [ENT]. This function can be used at any time on any observation screen. Each note can be up to 50 characters. The note is stored as a CO record in the raw data. To display a list of previously used notes, press the Stack softkey. The stack stores the last 20 notes. Then press [ENT] to select the note. This function is available from any observation screen. Modify the default point name for the next record.
Press [ENT] to confirm the new default point name. The new point name is appears as the default PT name on the input screen. Bubble indicator To display the bubble indicator in an observation screen, press. To turn the leveling compensators on or off, press []. When the leveling compensators are turned off, the text OFF appears on the screen.
The NPL has vertical axis adjustment only. The current setting of leveling compensators is indicated by header characters :, , :, and after field labels such as HA, VA, SD, and HD in observation screens. For more information, see Header characters, page Whenever you press a [USR] key, the function that is assigned to that key is activated directly. Hold down the [USR] key for one second to display the list of functions that can be assigned to the key.
If you highlight a menu item and then press [ENT], a sub-menu appears. The first item on the sub-menu ends with the text [MENU]. If you select this item, the whole menu is assigned to the [USR] key. For more information, see [USR] key settings, page Use this screen to change the type of data that is assigned to [DAT].
Press [ESC] to return to the previous observation screen. For more information, see [DAT] key settings, page List Display 3. If the Page Up icon appears, there are more pages before the current page. Press [] to move down one page. To select an item from the list, move the cursor onto the item and press [ENT]. The default name for a new point is the last point name entered, with the last digit incremented.
For example, if the last point name was A, the default name for the next point is A If the last character of the previous point name is alphabetic, the default point name is the last point name. When the cursor is in a PT point field, there are several ways to specify a point, or input coordinates. Entering an existing point When you enter a known point name or number, the coordinates of that point are displayed briefly.
A short beep sounds before the next screen appears or the next field is selected. The input coordinates are used in the calculation. They are not saved in the database. If the Page Up or Page Down icons are displayed, use [] to page up or page down the list. Recording an instant measurement You can also input a point by recording an instant measurement. To do this, press the MSR softkey. An observation screen appears.
To change the height of the target, press the HT softkey. To go to the point recording screen when you have finished the measurement, press [ENT].
Enter the point or code name. Press [ENT]. Press [ 3 Getting Started Entering a point from the stack The point stack is a list of recently used points. To display the stack, press the Stack softkey when the cursor is in the PT field. When you return to the point input screen, the selected point name is entered in the PT field, incremented by one. For example, if you selected the A point, A appears in the PT field.
The stack shows the last 20 point names used, in chronological order from last used to first used. Entering a point from the point list To display a list of existing points, press the List softkey when the cursor is in the PT field. When you return to the point input screen, the selected point name is entered in the PT field.
You can add digits or alphabetic characters if required. Entering a code For more information, see [COD] key, page You can use numeric or alphanumeric names up to 16 characters long to identify codes. Then use the keypad to enter the code. Entering a code from the stack The code stack is a list of recently used codes. The stack may contain up to 20 codes.
To display the stack, press the Stack softkey when the cursor is in the CD field. The selected code is copied to the CD field. When the instrument is rebooted, the code stack is cleared. Entering a code from the code list To display a list of existing codes, press the List softkey when the cursor is in the CD field.
For more information, see Editing an item in the point list or code list, page If you highlight a layer in the list and then press [ENT], the codes and layers in that layer are displayed. When you return to the input screen, the selected code is entered in the CD field.
Items are shown in alphabetic order. You can also use the first character search to quickly find a code. For more information, see Advanced feature: Searching for a code by using the first character, page Advanced feature: Searching for a code by using the first character To find a code quickly when the code list appears, use the first-character search. For example, to see feature codes that begin with T, use the keypad to enter the letter T.
To do this, press [1] twice. After each press of the key, the input mode field displays the selected letter. For example, if you press [1], S appears.
If you quickly press [1] again, T appears. If you do not press the [1] key again, the letter T is selected. Once you have selected a letter, the cursor moves to the feature code beginning with that letter.
If there is no code beginning with that letter, the cursor moves to the next available letter. You can register up to ten Quick codes. To register Qcodes, press the Edit softkey. For more information, see Quick code measurement mode, page Press the Edit softkey to change the Qcode. You can edit the entire code, or just the number at the end of the code.
You can still use [DSP] to change the background displays. Entering values in feet and inches To enter values in feet and inches in an input screen, enter the elements, separated by periods. If the denominator is 16, you do not have to enter it, and it is not displayed on the screen. For example, if you enter [2] [. If the denominator is 16, it is not shown on the screen.
Jobs 3. C Caution — Before you use the instrument for the first time, check the job settings. Creating a new job Press [1] to open the Job Manager. Press the Creat softkey to open the Create Job screen. Enter the job name.
Press the Sett softkey to check the job settings. You cannot free space by deleting records in an existing job. Creating a control job A control job, or common file, stores coordinate data that is used by several field jobs. You can create a control job in the office. Press [1] or select Job to open the Job Manager. Move the cursor to the job that you want to use as the control job. Press the Ctrl softkey. Press the Yes softkey. For more information, see Creating a control job, page When you enter a point name or number, the system searches in the current job first.
If the point is not found in the current job, the search is automatically extended to the control job. If the point is found in the control job, the selected point is copied to the current job as a UP record. Jobs prefixed with? If a job is from an earlier version, you cannot open it, set it as the control job, or display its job information.
However, you can use the DEL softkey to delete it. Jobs created in version 1. Download all jobs before you update the software that is running on the instrument. Measuring Distances 3. For information on how to assemble the prism reflector, see Setting Up the Prism Reflector, page Sight the telescope to see crosshairs at the center of the prism reflector. Measuring distances Sighting a tiltable single prism While the instrument is taking a measurement, the prism constant appears in a small font.
Each time a measurement is taken, the distance is updated. If the average count is set to a value from 1 to 99, the averaged distance appears after the last shot. The field name SD changes to SDx to indicate the averaged data. For more information, see Status bar, page For more information, see [HOT] key, page These settings are job-specific. If you need to change any of these settings, you must create a new job. For more information, see Job settings, page , and Settings, page Measurement settings Use [] to change the value in the selected field.
The symbol then constantly runs from left to right over the prism constant in the display. When an N-prism measurement is taken, the icon appears in the status bar above the battery icon. Incorrect Target settings may result in measurements outside the precision and intervals specified for the instrument. A measurement made immediately after changing the target setting may take a longer time than usual.
The Target setting is used to apply better cyclic-error adjustment in distance measurement. It efficiently eliminates multipath reflection. The MSR only setting is the default measurement mode.
The Confirm setting displays the Record PT screen before data is recorded. The ALL setting is a quick shooting and recording mode. The instrument then returns to the BMS for the next measurement. Setting the horizontal angle to 0 Entering the horizontal angle Use the numeric keys to enter the horizontal angle.
The displayed value is rounded to the minimum angle increment. Recording a foresight point after repeat angle measurement To activate repeat angle measurement, press [3] or select Rept. Sight the backsight and press [ENT]. Sight the foresight and press [ENT]. The horizontal angle is accumulated and the value is held again. To end repeat angle measurement, press [ESC]. When you have accumulated enough horizontal angle between the backsight and the foresight, press [MSR1] or [MSR2] to take a measurement to the foresight.
The averaged horizontal angle appears. This value is fixed until the process is finished or cancelled. Then press [ENT] to record.
Horizontal angle hold To set the horizontal angle to the displayed value, press [ENT] or the Set softkey. Station Setup 4. To select a command from this menu, press the corresponding number key. Alternatively, press [] to highlight the command and then press [ENT]. The last function used is highlighted.
Press [1] or select Known in the Stn Setup menu. Enter a point name or number in the ST field. Enter the coordinates for the point. Press [ENT] after each field. The Backsight screen appears. Select an input method for defining the backsight point. To enter coordinates for the backsight point BS , press [1] or select Coord in the Backsight screen. Enter the point name. If the point exists in the job, its coordinates are shown.
If you intend to take a distance measurement to the BS, enter the height of target in the HT field. Sight the BS on Face-1 F1. Press [ENT] to complete the setup. The QA screen shows the dHD and dVD values, which indicate the difference between the measured distance and the distance calculated from the known coordinates. To record the station, press [ENT]. To finish the station setup after taking a distance measurement, press [ENT]. ST and F1 records are stored to the current job.
To go directly to the Face-2 measurement after taking a distance measurement to the BS on Face-1, flip the telescope. Press [ENT] on Face The delta screen appears. To enter the azimuth angle to the backsight point, press [2] or select Angle in the Backsight screen. In the AZ field, enter the azimuth angle to the BS point. ST and F1 records are stored in the job. See Advanced feature: Measuring F1 and F2, page Setting up a station using multiple point resection Measurements can be distance and angle, or angle only.
Calculation starts automatically when enough measurements are taken. You can delete poor observations and recalculate if necessary. You can also select the BS point. If the angle between known point 1 and known point 2 measured from the station point is extremely acute or extremely oblique, the resulting solution will be less reliable geometrically. For geometric reliability, select known point locations or station point locations that are widely spaced.
To start the resection, press [2] or select Resection in the Stn Setup menu. Enter the point name for the first observation point PT1. Enter the target height and press [ENT]. The F2 softkey is not available on the NPL To proceed to the next point, press [ENT]. Enter the second point PT2 and its height of target. When the instrument has enough data, it calculates the station STN coordinates.
For information about the View softkey, see Advanced feature: Viewing and deleting a measurement in resection, page When the results are satisfactory, record the station. Enter the height of instrument, if required. To change the station name, move to the ST field and edit or replace the text.
For more information, see Others settings, page BS defaults to the first observed point. To change the BS, press the Change softkey. The minimum data required for a resection is either three angle shots, or one angle shot and one distance shot. If you use a distance shot, the distance between the target points must be greater than the measured distance.
Stn-Z is calculated from distance-measured data. If no distances are measured, then Stn-Z is calculated using angle-only measurements to points with 3D coordinates.
Advanced feature: Viewing and deleting a measurement in resection To check the measurements to each known point, press the View softkey on the calculated STN sigma or coordinate screen. Then press the DEL softkey. The STN coordinates are automatically recalculated. The input screen for the next PT appears. Setting up the station quickly without coordinates For the new point, MP 0, 0, 0 is stored as the coordinates. When the ST is manually changed to a known point name, the station is set up on the coordinates of the known point.
No default PT is assigned to the BS. Leave this field blank, or enter a BS point name. The backsight azimuth AZ defaults to zero, but you can change this. For more information, see Setting up a station with known coordinates or azimuth, page When the point is found, it appears briefly.
The cursor then moves to the HT field. The updated station coordinates are displayed. You can change the HI in this screen. When the HI is changed, the Z coordinate is updated before the station is recorded. You must complete a station setup before you use the Remote Benchmark function. This function always refers to the backsight point from the last ST record stored in the current open job. Enter station coordinates for observations without recording data 2.
To store raw data, use one of the other functions in the Stn Setup menu. This function does not store an ST record in the job. You can use this function without an open job. The current instrument XYZ values are shown as the default. The display returns to the BMS. Enter a known point as P1. If you enter a new point name, a coordinate input screen appears. Choose how you want to define a known line: — To define the line by entering P2 coordinates, press [1] or select By Coord.
If you select By Angle, the azimuth input screen appears. Enter the angle value and press [ENT]. A measurement screen appears. To check your measurement, press the DSP softkey. If you defined the line by entering the P2 coordinates, the difference of HD dHD and VD dZ between your measurement data and input coordinate data are displayed.
Enter the station name, the height of instrument HI , and a feature code CD if required. Backsight BS defaults to the first point P1. To change it, highlight the BS field and then press the Change softkey. Specifying the stakeout point by angle and distance To display the input screen for the distance and angle to the target, press [1] or select HA-HD in the Stakeout menu.
Enter the values and press [ENT]. When the measurement is completed, the differences between the target position and the stakeout point are displayed. You can use this menu at any time to change HT and T-P. Every time you press [DSP], the next screen appears. To record the stakeout point, press [ENT]. Press [ENT] to record the point. After recording the point, it returns to the observation screen.
You can continue observation, or press [ESC] to input another angle and distance for stakeout. To start a stakeout by coordinates, press [2] or select XYZ in the Stakeout menu. Enter the point name that you want to stake and press [ENT].
You can also specify the point by code or radius from the instrument. If several points are found, they are displayed in a list. Use [] to move up or down one page. Highlight a point in the list and press [ENT]. The delta angle and the distance to the target are shown. Ask the rodman to adjust the target position. When the target is on the intended position, the displayed errors become 0.
For more information, see Using [DSP] to switch between display screens, page To record the point, press [ENT]. The default value is For more information, see Stakeout, page After recording the point, the display returns to the observation screen.
If you selected a point from the list, the display returns to the list, unless all points have been selected. Press [ESC] to return to the point input screen. Enter the start point Fr and the end point To.
The range between Fr and To must be less than points. If existing points are found between Fr and To, a point list appears. To go to the stakeout observation screen, press [ENT].
If you have assigned a control job, and additional points are found in the control job, the Ctrl softkey appears under the list. It then guides you to stake out the points, one by one. Set up the baseline. Enter the total stake number in the Span total field. The observation screen for the first stake from the instrument appears. You can calculate and guide up to double the number of the stakes.
Enter the first point P1 of the line. If you press [ENT] without entering a PT name, you can enter temporary coordinates which are not recorded in the job. Alternatively, press the MSR softkey to measure a point. Enter the second point P2 of the line. Enter offsets to the line. Press [ENT] in a blank field to enter the value 0.
When a distance measurement is taken, the difference from the design point appears. This function works as in the angle-distance stakeout.
Measuring distance and offset values along a specified line Press [1] or select 2Pt RefLine in the Programs menu. Enter the first point for the reference line. Alternatively to enter the point by measuring , press the MsrPT softkey. The Record PT screen appears.
Enter the second point for the reference line. A list of matching points appears. Highlight a point in the list and then press [ENT]. Enter the point name and feature code. You can also use this screen to change the HT value. Press [2] or select Arc RefLine in the Programs menu. Enter the start of the curve point P1 and the azimuth of its tangent line AZ1. To enter P1 by direct measurement, press the MSR softkey. Choose a method to define the arc. P2 can be any point on the tangent line that is to exit the curve.
In the radius Rad field, enter a positive value for a clockwise curve. Enter a negative value for a counterclockwise curve. When all factors have been entered, the instrument calculates the curve. If the curve length Len is too large for a circle of the given radius, it is shortened. To record the point, press [ENT] on any observation screen. The arc is stored in comment records. The distance from the station point to the first point appears. The distances between the first and second point are displayed.
To change display screens, press [DSP]. Default point numbers are displayed. You can change these point numbers. To record a note, press [ENT] in the To field. For more information, see RM records, page Measuring between the current point and the immediately preceding point 1. Follow the procedure as for a radial RDM measurement. For more information, see Measuring between the current and the first point measured, page The preceding two points are subject to calculation.
Calculations are made with reference to the first point. Enter the height of target. Loosen the vertical clamp, and turn the telescope to aim at an arbitrary point. The difference in elevation Vh appears. All Auction Buy It Now. View: Gallery View. Product Total Station see all.
Buying Format All Listings filter applied. Free shipping. New Nikon BC 7. Only 1 left! Results Pagination - Page 1 1 2 3. Nikon One stop shop for all things from your favorite brand.
Shop now. You May Also Like. Canon Vintage Movie Cameras. Leica Camera Lens for Panasonic. Get Nikon Total Stations Accessories for Surveying Whether you are performing general land surveying or mapping out a building construction site, a total station can provide you with the data you need.
What types of accessories are available for total stations? Accessories devices can include: Tripods: Made from various materials that act as a mount for a total station. Poles: Aid with balance and stability. Eyepieces: Designed to use a multitude of ancillary lens sizes.
Carriers: To provide protection during transportation.
0コメント